Products, View Outlet works fine. In either case, a new vacuum hose of good quality should fix the issue. 3 things are key, 1. Hi Tracy, the C48 number is not the pump model, but the motor number. If assumed to be the capacitor, get the MFD number printed on it, and find an exact replacement capacitor on our site, or from a local electric motor shop. Especially a drip from the clamp band or the threaded fitting on the outlet port of the pump, or a dripping shaft seal, or leaking housing. The pump said it came prewired for 230V, but we are running 115V. The higher the pump is elevated above the water level, the more struggles this can cause. Now that i have my new liner in and pool is filled i started adding chemicals to the pool and i went to turn the switch on and there is nothing happening with the motor. Inspect for any damage to wires or wire casing. We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. I have a Hayward H250, when I turn it on the green heat light is lit and the heater seems to make a howling sound. spun and is loosely spinning. Ive tried everything. Read up on it and seems it happens a lot and the motor drive needs to be replaced. that sounds like loose wires, or broken wires. When I installed the filter and pump the water in the filter came gushing out of the filter and the top mount was raised up even though the clamps were tightly screwed in place. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. dual-speed pool pump. Second thing could be loose wire connections, on the breaker, on the outlet, or on the cords connecting to the pump/trol, or damaged plug ends. NO one can get the cover off the darn thing. We have a Hayward Aqua Plus system. There should be no continuity. However, many inground pools do not run the pump 24/7, but operate it from 12-18 hrs daily, depending on the need, and the ability of the filtration system and sanitation efforts, etc Some small systems do need to run 24/7, but a properly sized system has a timeclock, to set it to run for around 12 hours per day (less during cool periods, more during hot spells)>. I just have a problem with the motor pump, I turn ON Saturday morning and left all day working, On Sunday morning I try to turn on the pump but it only make a noise but water dont flow then it stop working, then on Monday do the same thing it only make noise for 3 minutes then it stop working. Fix this problem simply by tightening or adjusting the wires and connections in the motor. That could explain the pumping problems. I assume from your post that there are 2 possibilities 1) bad capacitor (I assume I can spot it visually) or 2) frozen shaft or propeller (how do I spot it and fix it? Got another one, it too is doing the same thing. When this has been corrected, shut the power down to the pump and rest it after 15 minutes. Hi, I have a H250PED2. I have cleaned the rubber gasket, made sure the springs touch to no avail. Hi Sam, I suppose a dead battery (capacitor), but there would be some noise or hum, as the motor tried to start, then would trip the breaker. Scrape out the old gasket with a sharp screwdriver and glue a new one in place with dabs of superglue gasket flat side down, ridged side up. I was going to try one of those next, as it seems impossible to keep water in the line without it draining into the pool. I would guess this is what is happening, and if so your service company is either uneducated or dishonest. We are a registered 501(c)3 non-profit that is funded by user donations. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? I even tried another new housing gasket and it still leaks. Hi the strainer housing must need to be tightened up. Went on to fill with water again & put on normal cycle and still was not getting a full prime. Also that some circuit breakers used can create such noise as to cause problems with this error message. You can buy replacement drives I believe, that may be the (expensive) cure for the problem. "
I have a Hayward super flo matrix pump. The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. the , . that is quite unusual, the 3/4 hp Super II is designed to pull much less, probably around 12 amps. Usually the capacitor (9 oclock) or the thermal overload switch (12 oclock) must be removed to gain access to the shaft, whereupon you can use an open end wrench to grasp the shaft and turn it slightly, back and forth, to break the rust free. 2 No loss of water level in the pool If control input data is corrupts, the heater will shut down and lockout. Be sure that all pool valves are open and any wall plugs are removed before turning on pump. No matter what setting I put it in its backwashing the sand into the skimmer. Check the impeller and seal alignment. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). I replaced the start capacitor as that sounded like that was the most likely culprit based on everything I read, but noise still persisted. So, it either needs a new motor, or new internal parts, or possibly a whole new pump. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). Hi check that the pump is not drawing air in, most common areas are around the pump lid, drain plugs and most common, the threaded pipe coming into the pump, which should be sealed with thread sealant like Teflon Tape and/or RTV silicone. Hi, each pool filter system has a different pressure, but if there was a normal pressure, many systems are designed to run around 10 psi (clean). So, when a pump is surging or pulsing, and not getting up to full head it is either starved for water, because of closed incoming valves, or too big of a pump for too small inlet pipes or because of air being pulled into the pump from air leaks or low water level in pool or from some obstruction in the lines, pipes or valves, a clog or something broken off I have found a Drain King useful in diagnosing such things, find at a hardware store, the 1.5-2 model, and connect to a garden hose, to pressurize pool systems and pipes, to look for leaks, or used as a water hammer to force clogs out, back the other way. Thanks, good question. Pull out on the dial, and reset it, until you feel the gears engage. I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker. Make sure the stationary switch, triangular shaped, screwed in at 6 oclock, is tight and intact. Or it could be an obstruction in the impeller, or anywhere before the impeller (clogged pipe, small pipe, partially closed suction valves, air leak) all of which will produce lower than normal filter pressure. And make sure the bolts are tight of course. "width": "611",
If not, use an outlet tester or plug in a different appliance (light, hair dryer, fan) to see if the outlet has power. Pump flow rates are found on pump flow rate curves. I removed the back of the pump and the yellow wire has a small black burn hole in it. I tried to prime the pump but it still doesnt kick over to cycle anything. If very clogged, you can usually tell, because debris will float out and you can grab some of it with your fingertips or with pliers. Chapter 1: The Evil Emperor's Son. Give the cell an acid soak and it should clear the blockage. We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. "datePublished": "2/24/2015",
This noise does not happen when the water is flowing through the heater but it is not turned on. You need to be really sure about the actual salinity reading. hayward blue essence troubleshooting - Lyriclifeclothing.com If you program the incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. "@type": "ImageObject",
*new pool owner of a big above ground pool* hello I bought a home it came with a pool the pump says Hayward. Could it have shut it self off from overheating? If you have other questions, you can email me Davy, at swimmers@intheswim.com. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. Disconnected the chlorination device, and direct connected it eliminating that. Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). In such case, filter pressure is lower than normal, if the impeller is clogged. WTF! Reconnect the pipes and test it out! The Tristar VS would be a good choice and easy to plumb, since its the same pump. You are using an out of date browser. i have an in ground pool. Any suggestions? stranger things backpack hot topic. If the yellow dial is bent, or the switch is bent, or the timer dog is broken or mispositioned, it can bypass the timer dog and not shut off hope that helps!?! If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. No special tools or lube needed. Please help. Are you using DE powder or enough DE powder? Hi Gail, overheating can be caused by the wrong wire size from breaker to motor, or loose wire connections, or over-voltage coming into motor, or lack of ventilation around the motor (mulch piled up, or big bushes close by, or placed in a box cover), but its can also be a fatal fault inside the motor. Hi Doug, could be a bad breaker, or bad wiring between the pump and breaker. We were cleaning our pool filter one day and went to restart the pump and it didnt. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. The blower will continue to run. Tonight, I tried to manually start the filter and all I hear is a click in the mother board. Should I shut down my system until I can get this fixed or is it safe for the motor to continue operation? Other timers will have a different switch, but all should have someway to override. If valve is closed but flame is sensed the blower will run for 5 seconds, then start a new ignition sequence. HI, that is usually a weak motor capacitor, which is a battery used to help the motor get up to 3450 RPM quickly.
Gaylord Palms Disney Shuttle, Friends Not Happy For Your Success Quotes, Prendere Imodium Preventivamente, Quarter Horse Sperm For Sale, Articles H
I have a Hayward super flo matrix pump. The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. the , . that is quite unusual, the 3/4 hp Super II is designed to pull much less, probably around 12 amps. Usually the capacitor (9 oclock) or the thermal overload switch (12 oclock) must be removed to gain access to the shaft, whereupon you can use an open end wrench to grasp the shaft and turn it slightly, back and forth, to break the rust free. 2 No loss of water level in the pool If control input data is corrupts, the heater will shut down and lockout. Be sure that all pool valves are open and any wall plugs are removed before turning on pump. No matter what setting I put it in its backwashing the sand into the skimmer. Check the impeller and seal alignment. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). I replaced the start capacitor as that sounded like that was the most likely culprit based on everything I read, but noise still persisted. So, it either needs a new motor, or new internal parts, or possibly a whole new pump. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). Hi check that the pump is not drawing air in, most common areas are around the pump lid, drain plugs and most common, the threaded pipe coming into the pump, which should be sealed with thread sealant like Teflon Tape and/or RTV silicone. Hi, each pool filter system has a different pressure, but if there was a normal pressure, many systems are designed to run around 10 psi (clean). So, when a pump is surging or pulsing, and not getting up to full head it is either starved for water, because of closed incoming valves, or too big of a pump for too small inlet pipes or because of air being pulled into the pump from air leaks or low water level in pool or from some obstruction in the lines, pipes or valves, a clog or something broken off I have found a Drain King useful in diagnosing such things, find at a hardware store, the 1.5-2 model, and connect to a garden hose, to pressurize pool systems and pipes, to look for leaks, or used as a water hammer to force clogs out, back the other way. Thanks, good question. Pull out on the dial, and reset it, until you feel the gears engage. I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker. Make sure the stationary switch, triangular shaped, screwed in at 6 oclock, is tight and intact. Or it could be an obstruction in the impeller, or anywhere before the impeller (clogged pipe, small pipe, partially closed suction valves, air leak) all of which will produce lower than normal filter pressure. And make sure the bolts are tight of course. "width": "611",
If not, use an outlet tester or plug in a different appliance (light, hair dryer, fan) to see if the outlet has power. Pump flow rates are found on pump flow rate curves. I removed the back of the pump and the yellow wire has a small black burn hole in it. I tried to prime the pump but it still doesnt kick over to cycle anything. If very clogged, you can usually tell, because debris will float out and you can grab some of it with your fingertips or with pliers. Chapter 1: The Evil Emperor's Son. Give the cell an acid soak and it should clear the blockage. We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. "datePublished": "2/24/2015",
This noise does not happen when the water is flowing through the heater but it is not turned on. You need to be really sure about the actual salinity reading. hayward blue essence troubleshooting - Lyriclifeclothing.com If you program the incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. "@type": "ImageObject",
*new pool owner of a big above ground pool* hello I bought a home it came with a pool the pump says Hayward. Could it have shut it self off from overheating? If you have other questions, you can email me Davy, at swimmers@intheswim.com. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. Disconnected the chlorination device, and direct connected it eliminating that. Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). In such case, filter pressure is lower than normal, if the impeller is clogged. WTF! Reconnect the pipes and test it out! The Tristar VS would be a good choice and easy to plumb, since its the same pump. You are using an out of date browser. i have an in ground pool. Any suggestions? stranger things backpack hot topic. If the yellow dial is bent, or the switch is bent, or the timer dog is broken or mispositioned, it can bypass the timer dog and not shut off hope that helps!?! If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. No special tools or lube needed. Please help. Are you using DE powder or enough DE powder? Hi Gail, overheating can be caused by the wrong wire size from breaker to motor, or loose wire connections, or over-voltage coming into motor, or lack of ventilation around the motor (mulch piled up, or big bushes close by, or placed in a box cover), but its can also be a fatal fault inside the motor. Hi Doug, could be a bad breaker, or bad wiring between the pump and breaker. We were cleaning our pool filter one day and went to restart the pump and it didnt. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. The blower will continue to run. Tonight, I tried to manually start the filter and all I hear is a click in the mother board. Should I shut down my system until I can get this fixed or is it safe for the motor to continue operation? Other timers will have a different switch, but all should have someway to override. If valve is closed but flame is sensed the blower will run for 5 seconds, then start a new ignition sequence. HI, that is usually a weak motor capacitor, which is a battery used to help the motor get up to 3450 RPM quickly.